Reliability EngineeringCCF

Common Cause Failure

A common cause failure occurs when one shared cause leads to the failure of two or more components, channels, or redundant systems.

What this term means in maintenance

A common cause failure occurs when one shared cause leads to the failure of two or more components, channels, or redundant systems.

Common shared causes

Examples include:

  • Shared power loss
  • Flooding
  • High temperature
  • Contamination
  • Maintenance error
  • Design defect
  • Common software fault
  • Fire
  • Incorrect procedure

Practical example

Two redundant pumps fail because both suction lines are blocked by the same contamination source.

Why it matters

Redundancy may provide little protection when components share a vulnerability.

Controls

Possible controls include physical separation, diverse design, independent utilities, separate maintenance actions, and common-cause analysis.

Common mistake

Counting installed standby equipment as independent without reviewing shared power, controls, environment, and maintenance.

How this term differs

Common Cause Failure is multiple failures caused by one shared event or condition. It is related to Common Mode Failure, Single Point of Failure, and Redundancy, but these terms describe different records, measures, roles, strategies, or decisions and should not be used interchangeably.

Keep exploring connected CMMS, reliability, and maintenance planning terms.

Glossary FAQs

What does CCF stand for?

CCF stands for Common Cause Failure.

What causes common-cause failure?

Shared power, environment, contamination, software, design, procedure, or maintenance error.

Why does it matter for redundancy?

One shared cause can defeat several redundant components at the same time.